What is the Difference Between MCCB & ACB & VCB
Answer Posted / kareem
1. MCCB: - is Moulded case circuit breaker.
2. ACB: - is air circuit breaker.
3. VCB: - is vacuum circuit breaker.
.All is of different type with same
Functioning.
.All of them are used to isolate the power or to trip the
Power at the time of fault in line and thus save the
Circuit from further damage and isolate unhealthy part from
Healthy one,
1. MCCB is stand for moulded case circuit breaker. It is
for
Medium voltages.......
2. ACB:-air circuit breaker which use quenching device as
air and used up to 3000 Amps and used up to 11KV to
33KV......
3. VCB:-vaccum circuit breaker which use ark quenching
device as a vaccum and used from up to 33KV to 220KV....
| Is This Answer Correct ? | 11 Yes | 2 No |
Post New Answer View All Answers
What will happen to the protection and metering, if the polarity of a single or two PT/PTs in three phase system is reversed? Please provide reference if any.
i want to run 11kv star connected motor in 6.6kv with delta connected throught inverter, is it possible?
What are the weight of 800KV DA,DB and DC type tower ?
we have two generators different capacity on 15 MW and other 6MW at 11 KV , 15 MW gen. bus short level current 40KA,and 6MW short level current 25KA,, length of cable 100MTR between 6 MW from 15MW gen. for bus coupling . kindly tell any one can we use both NGR OR one NGR from any GEN. BOTH NGR has diff. rating. Tariq pakistan
in Contactor opearation Why there is a difference in the values of the operate and release voltage in case AC supply
draw singleline diagram of star to delta and dol starters
In the magnetic fluxes, what is the role of armature reaction?
What is effect of over voltage and under voltage on ACB
tell me about roaster switch .& what is the function in transmission & distribution?
What willbe change in programming when we use 5/3 solenoid inplace of 5/2 in operating of a cylinder?
Advantages of using generator circuit breaker (GCB) scheme in a power station ?
what is the ATS .And how it works.
Dear sir, my knowledge about cable size determination is limited. Though I read examples I could not calculate the Cable size required for electric driven pump 40 KW, 380 Volt, 50 HZ, 50 meter from transformer and it is three phase star delta starting. Please help as there is no one in my surroundings to help.
What is Electrical Grade Aluminum for Tubular BusBars. i am confused between 6063 and T6 or T5 and what is BS 2898 and BS 159?
What is the criteria that generally follow by distribution licenses to fix contact demand of their industrial customers?