Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what are the difference between protection class CT and
Class PS CT

Answer Posted / r.suryamuthuraman

if any fault occurs core needs to saturated for protection
of ct.because ct secondary ckt will goes to relay current
coil .secondary ckt of ct will having resistance and
current.to avoid saturation want to decrease the burden of
ct.ps means special protection having high accuracy than
other class

Is This Answer Correct ?    0 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

if two transformers are placed parallel & both have fault impedance of 50KA will it increase or decrease show example?

1941


defination of transistor controlled series capacitor

2588


why booster transformer is used in sumpners test conducted on transformer????

3512


How to find out damper winding failure for synchronous machine?

1440


How to assume answer to electrical questions

1472


If the Brush of DC motor is shifted by 90 deg, then what happens to voltage and torque? Both voltage and torque are zero. how to justify the answer?

1378


I am inpecting a 10kVA UPS what tests should i do and should i observe?

2161


how to select size of hardware for linking aluminium busbar is it depend on area of busbar or current flowing through bus bar

1961


What are n circles?

1032


-What shall be short circuit current of LV switchgear for a 1000 kva, 11.415kv, 3 phase tranformer with 5% reactance.

2065


for 100 HP Induction motor service factor is 1.2(SF) we placed a VFD at the motor side load is balance with 0.3 Amp's Phase to Phase but at incoming of VFD load is un-balance with 10 to 20 Amp's what will be cause of load un balance

1891


what is the most permissible winding temp when we conducting a generator load test?(condition no load)

1662


What are the parameters of water ( Water quality )to be monitored in Centralised HVAC ( water cooler chillers )

2008


we use capister for power factor. when we use capaciter in dg circuit  than defect dg. can we use capaciter bank for dg circuit

1858


What are the material used for inductance coil?

1085