why, when birds sit on transmission lines or current wires
doesn't get shock?
Answer Posted / pratik
when birds sit on transmission lines, the potential between
two legs of it, would be very low.Also, it body has its own
resistance to withstand minor current following from his
body thats why it doesn't get shock.
for examples it body offers resistance R= 1000 ohm (Approx.)
and potential difference between two legs V=1V (Approx.)
then current following from its body I=1/1000 = 0.001A
which doesn't harm its body.
| Is This Answer Correct ? | 9 Yes | 20 No |
Post New Answer View All Answers
The knee point of a current transformer is normally unique and known.So why in the nameplate of a CT they put the minimum value like this Vk> 400v.
ow can i get certificate of competency as electrical supervisor and my diploma in electrical engineering from jalgaon.
I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?
While performing stability test of differintial cts how to know the voltage and current on both side of the transformer?
why should the primary of transformer be connected in delta in a heat run test?
please send me previose rrb junior engineer qustion papers
Electrical 'C' license full abbreviation , and full form
Is it possible to measure the voltage of a battery from a single terminal?
I have 2 KW electric water heater.I am gonna use it in controlling water temp.so I needed to increase or decrease the heating capacity.is there any electrical-electronic circuit for varying the resistance & so current?
What is milivolt dop test in Busducts? What is its significance & procedure to do the test?
Load break swicth maintenance procedure.
1) why a dg set shows variation of power factor and load when synchronised with other dgs? 2)Why the load sharing is not become equal in all dgs?. 3)When a dg set will not run on auto start?
hai iam arunkumar. i have applied for an section enginner in rrb. i want lat 5 years solved question papers. if u have please sedn it to arun30682@gmail.com
A 230V dc shunt wound motor has an armature resistance of 0,15Ω.When operating on no load at 650 rev/min the armature current is 6A . The motor takes a full load current of 85A. Calculate the full load speed if the field flux is (i) maintained constant (ii)reduced by 0,03
Explain how you intend to work under pressure to meet up with deadline target?