Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Explain the working principle of Synchronous Generator and
Assynchronous generator?

Answer Posted / prasanth kumar

The word synchronous suggests that the rotor shaft runs at
synchronous speed,Ns=120f/p.when dc supply is provided to
the rotor shaft,it starts rotating in synchronism thus
developing 3phase alternating voltage on stator winding
which s then taken out...

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is magnetizing current test in power transformer

2704


how power is generated,and transmitted to our home..pls explain briefly in simple words.

2216


what is meant by impulse voltage?

1973


State ohm’s law?

1067


Is it possible to make a 5P10/ CT Ratio 50/1A Burden 5VA

1692


what is the function and use of cable differential protection relay?

2871


what is the size of ht cable of 33kv ht line and transformers ratings are 1 Mva and 5mva.please send formula also.

1418


What technology is used in latest generators?

2066


write down the formula of cable size in RM if current is 50Amp.

1309


what is the difference between general inverter and solor inverter clerly explain plz

2074


Why does the Solid state Rectifiers for 3-ph brake motors sometimes have 2 & sometimes 3 output terminals?

2064


Power factor =1.000 at factory in supply. However, PF = 0.8 at motor end. Current = 100 Amp, Voltage = 400 V. What is the power distribution loss? Can I reduce it by adding capacitor at the load feeder?

2019


do we use neutral grounding for resistive balanced load? if we use what happen?

1757


draw the block diagram of fire alarm?

5387


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2110