why test lamp didn't glow across 500v megger?
Answer Posted / vasudevan.m
Megger normally operate in DRY CELL ( Digital megger) or
electro magnetic induction (analog megger). so the current
flow at the output terminal of the megger is very very low
which is not sufficient to make the lamp to glow.
| Is This Answer Correct ? | 4 Yes | 3 No |
Post New Answer View All Answers
at work we have a 3 phase motor but on testing one phase isnt getting a reading. it runs 24 hours a day all week. stops and starts well no noise or heating. the phase isnt down to earth.is it just a bad meter reading or not? phases one and three came up with a resistance reading of 0.4 but phase 2 couldnt get anything shows up as open circuit.
what are all types of cross section in AC cables?
How halogen & merquery lamp works.
How do I calculate a WTI CT ofa 1250kVA 6600/400V transformer
What is the kiosk parts, about them and their functions ? If anybody have some PDFs files or details about this plz send it on tawhidfaisal@Yahoo.com
A double circuit with dog conductor 66KV Transmission line from wind farm evacuation to feeding substation having capacity of 25MW for transmission. Can same transmission network be considered for further expansion of Power & how much in MW. If we need to expand next 10-15 MW more will there any augmentation is required in transmission network? Kindly reply asap.
What aturn on methods of scr?
3Cx240 & 3Cx300 sqmm Al. cable from lv side. What is the calculation for this cable??
Why field rheostat is kept in minimum position while armature rheostat at maximum position?
What size cable (based on voltage drop) is required to supply a 40 A three phase boiler if the wiring system is 75V single insulated cables installed in non-metallic rigid conduit 56m from the main switchboard? Voltage drop in the consumer's mains is 8V.
According to IEC60034-14, When the vibration monitoring system required for motor Bearing. above which KW, it is required? and for what type of bearing the vibration probe is provided.
What is the effect on power factor, shown by a trivector meter; incase of reverse phase sequence. If the power factor of a system is lag what meter will show in case of reverse phase sequence connected to the meter. and What in case of lead.
What are the advantages & disadvantages of a group electrive drive?
Whether the vacuum contactor requires Short circuit protection?If No,why?
What is the exact minimum vale of voltage between an earth and netural which can damage or can do malfunction of the electronic equipments ? If this is mentioned in any book, pl.give reference.