Why voltge arev transformed in to 132KV/66/KV/33KV like
that
Answer Posted / ankur
Vrms=Vpeak/sqrt(2)
Vavg=(2/pi)*Vpeak
Vpeak=(pi/2)*Vavg
so,
Vrms=(pi/(2*1.414))*Vavg
to get a average of 100Volt
the rms comes to be a multiple of 111V
so all voltages are multiple of 1.11
@Sonal: even 132 is 12*11
Is This Answer Correct ? | 6 Yes | 1 No |
Post New Answer View All Answers
A 100W electric lamp is supplied from a 115V, 60HZ source. The peak instantaneous power dissipated in the lamp filament is
I have two PLC processors. I want to communicate both processor with each other. How i can do so?
If SFU is Switch Fuse Unit, What is the expansion for FSHF in Electrical Engineering?
How to arrange a hous hold earthing system to keep minimum earth resistance( below 7ohms).
What is difference is of VSD,VFD,VSDS, are they the same as the direct current to control dc using above mention
need to make a report. Need to choose a 3phase induction motor. Load conditions motor will operate in : Maximum Load: 30 Kw Speed: 2950 rpm Ambient temp: 20 cent Supply voltage: 440V Frequency: 50Hz need to look for the safety factor when choosing the motor, went through catalouge found a few, but dont know how to choose the safety factor allowing an extra load something above 30 KW to avoid any harm.
why the NGR (neutral grounding resistor) always OFF during DG off?
what heppend if we are connected u1-v1-w1 as a star point in the place of u2-v2-w2 in power genration
sir please tel me how calucalte kwh if home taken load 30ams how maney kwh taken per day.and 3phase motor 5hp per hars how maney load teken and how mach kwh and forward me to electrical table for calicalte kwh and kvr and kvah
A 3-PHASE TRANSFORMER IS USED TO STEP-DOWN THE VOLTAGE OF A 3-PHASE, 11KV FEEDER LINE. PER-PHASE TURNS RATIO IS 12.FOR A PRIMARY LINE CURRENT OF 20A, CALCULATE THE SECOUNDRY LINE VOLTAGE, LINE CURRENT AND OUTPUT KVA FOR FOLLOWING.A)STAR- DELTA.B)DELTA-DELTA.
How to calculate MCB Breaking capacity.
If I want to connect a capacitor bank on the HT side of a 11kV/415V, 3 phase delta-star distribution transformer to supply Reactive power to it..what practical specifications of a Capacitor bank that can i've??please reply..
if we install two earth pits with a clear space of 5m without any interconnection,by checking the digital multimeter will it show continuity between earth pits? If so what would be the approx. value
Is potential difference materials property ..? if yes tnen how.. explain brifly.
what should be the acceptrd value of winding resistance for 2.5MVA transformer