Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why Methanol used in KF Titration?

Answer Posted / prasadarao.k

Methanol Used for all samples will be dissolved in that
solvent,and also Methanol used for to neutralized the KF
Solution.

Is This Answer Correct ?    30 Yes 7 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the origin to prepare standard operating procedure

2331


What is similarity factor?

1206


What if impurity area in control sample coming more as compared to LOQ level of impurity ?

1601


on saturation solubility study data how we can find out the bcs class of drug?

899


How to compare XRD graphs against standard and carry polymorpism study of API's by powder XRD method?

3864


what is the purge flow & how to calculate

2648


why salisylic acid not using now days for disdolution calibration?

772


How to set analyticl specification for combination products?

747


what is the structure of DOWEX-50

5521


Please tell me about the pH of Polycaboxylic ether is it in the 5-6 range ever or more than 6

2609


Why dissolution test is not performed in all of the products

2537


how we can identify the impurity is coming below loq at transfering site?

872


I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?

3540


1.What is the difference between method validation and method verification 2.Which guidelines proposed to method transfer

1852


from where i get mortar pastle for glass bottle crush? it's required for testing of it?

2267