Input power is 380 - 450 V but with 45 - 55 Hz frequency -
desired output is 415 V and 50hz with 1% variation
permissible. CVT / Servo dont stabilize the Frequency -
what is best solution??
Answer Posted / k.prakashchandra
Frequency is dependent on the prime mover, the speed
regulation of which, is very bad.
Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
why steady state stability limit is greater than transient stability limit ? How it can be explained ?
how can i apilly for electrical c licencese.sir,i completed B.Tech in electrical & electronics engineering in 201onot working any company
what is the minimum clearance between a 11KV 150KVAR capacitor cell and series reactor.can a series reactor can be mounted in the same structure of the capacitor cells structure
what is the meaning of impedance protected in instrument cooling fan
Why slip ring ind. motor power consumption is low compare to induction motor .same 90 kw motor used same load output
1)what is the function of a frequency inverter? 2)If a few frequency inverter are connected onto a device network,what are the two setting that will ensure the frequency inverter work properly on the network. 3)whats is the name of the input sensor for weigher? 4)How to confirm that the load cellis faulty? 5)Describe briefly the steps to validate that the weigher is working properly? 6)Describe the procedure to validate the flowmeter accuracy? 7)Describe briefly the steps to validate that the tempreture sensor/transformer is working properly. 8)what is the adjustment that need to be done when you are calibrating the temperature transmitter ? 9)what are the safety measures to be taken before disconnecting motor for rewinding. 10)whats is the synchronous speed in rpm of typical 4pole 50hz motor? 11)whats is the formula for kw, ohm's law 12)if a 3phase motor is rated 3kw,415vac,what is it's rated ampere?
List the advantages of star-delta starter with induction motor?
what is stper motor
Logic using 1 kV or 1,1 kV grade in house wiring Low voltage cable. Explain/suggest? some use 1kV and some prefer 1.1kV grade insulation low voltage cable why??
63MVA,220KV/6.9KV Transformer LV side neutral is connected to Earth pit through NGR. Whether this earth pit required to connect with near by below grouding earth mat or it is to be kept separate?
A 50Hz,4-pole,3-phase,star-connected synchronous motor has a synchronous reactance of 12ohmsper phase and negligible armature resistances.the excitation is such as to give an open-circuit voltage of 13.2kilovolt.the motor is connected to 115kilovolt, 50hertz supplying. what maximum load can be the motor torque,line current and power factor?
Why generation voltage in thermal power plant is between 11kv to 33kv?
Please define ohm’s law for a.c (alternating current)?
In single phase capacitor motor, if the motor rotate reverse direction then how much power will be consumed by the motor and why?
What is inductance?