Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what r the reasons to get peak telling?

Answer Posted / nageswar rao

the following parametrs are reasons
1.silinol interaction of basic amines
2.adsorption of acidic compounds
3.mass overloaded
4.injecting sample in worng solvent significantly stroger
than mobile phase

Is This Answer Correct ?    15 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Many times I don't got a caffeine peak in calibration of hplc using guard column ❓

1825


How to start the dissolution development for unknown tab?

1689


I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?

3540


mahagenco syllabus for the post of chemist

6481


function of detecter in hplc ,gc and spectroscopy? function of carrier gas in gc?

2674


We use Potassium Dichromate solution for the calibration of UV-Visible Spectrophotometer in UV region. My question is to calibrate visible region which solution could be used in photometric accuracy

1909


WHY pKa value is more important than pH value of the mobile phase in HPLC?

1773


What is aggregate and fragments in SEC?

2117


What is the calibration of uv process and preparation

2000


how decide the clining method and cleaning method validation require for this perticular products?

766


how a particular wavelength can be different for a particular compund while analysing by uv and by HPLC.

2309


In HPLC calibration, caffeine is used as primary standard for wave length calibration due to caffeine is having dual maxima at 273 & 205 nm and one minima at 245 nm. Any body can give reference of these details from any pharmacopeia (with chapter no.) or any other authentic guideline?

1973


for which product require to do content uniformity? what is limit of cu?

821


what is the structure of DOWEX-50

5521


What is the use of tlc and hplc? And when and where use?

1168