Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

For a CT the number of turns in the primary winding is.........

Answer Posted / sanjeev shukla

actually we cant say about the no. of turns of the primary winding of the ct but the rating of the c.t is 800/400/200/1 means what should be the primary current secondary current must be 1 amps

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the significance of tan&delta and how it performed in power transformer

1926


Difference between transition and diffusion capacitance

2965


What are the main significances of root locus?

1224


Which motor will you choose which can operate in both lagging as well as leading power factors?

1142


why using transformer and thyristor switch in 3 phase apfc panel

2867


how many types are their in switchyard or substation(like D,I TYPE), what is differant between them

2108


What happened ,If 3 phase clearance not maintained in 33KV Line,11KV LIne etc?

2348


What is gain margin?

1071


what is the formula of starting current of 3phase and 1 phase motor???

2319


Hello Guys !! i want to rrb section engineer electrical(signal) previous model papers? any body help me?

1893


How much of the total hydro power potential has been exploited so far in india?

1111


Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1.  H1-H2 = H2-H3 H3-H1 2.  H2-H3 = H3-H1 H1-H2 3.  H3-H1 = H1-H2 H2-H3 For the LV side also: 4.  X1-X0 = X2-X0 X3-X0 5.  X2-X0 = X3-X0 X1-X0 6.  X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0  H2-H0  H3-H0    X0-X1  X0-X2  X0-X3 128.0  119.9  7.2      29.2   13.3   15.8 70.7   128.4  59.2     23.4   22.0   3.6 7.2    120.1  128.1    13.4   29.3   15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?

1851


Anyone who can recommend an equivalent to Envirotemp FR3 of Cooper?

1953


what is load vs Torque curve & why it is used?

2061


What is the difference between multimeter

1956