Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

HOW TO FIND THE PRIMARY AND SECONDARY OF TRANSFORMER(IN OFF
CONDITION) USING MULTIMETER? IS IT POSSIBLE FIND BY SEEING
RESISTANCE???

Answer Posted / rahul bawangade

as per working principle transformer , there is no primary &
secondary of transformer . transformer can be work in either
ways.

but if we have to check HV & LV we can do with multimeter .
as per transformer ratio

V1/V2=N1/N2=I2/I1. ................eqn 1
&
R =rho L/A . ...............eqn 2
\
as LV side requirement of current more & no of turns are
less , & cross sectional area of conductor is lare as per
eqn no.1& 2,resistance offered by conductor is less as
compare to HV .

Is This Answer Correct ?    11 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to calculate the phase to phase clearness of HT /// LT bus bar?????

2084


1. What is maximum permissible distance between smoke detectors ? 2. How do we decide number of smoke detectors required in a large office, warehouse, hall etc ? 3. What should be maximum height of smoke detectors ? 4. Where do we use heat detector, optical smoke detector, temperature sensitive detector ?

2918


Give some differences between open loop and closed loop control systems.

1178


As per the Anchor capstan motor specification, full load current is 200A. starting current is 1750 A and acceleration time is less than 8 seconds. Please guide for selection of cable size.

1852


if we have 320KVA Genset kindly advice how much load we can put it.

1531


Why Transformer Neutral having one earth pit ( more earth electrode resistance) whereas body have many earth pit ( less earth electrode resistance)?

4334


we are having 110 Kv,250mA Electrostatic precipitators for coal fired boilers. what will be static voltage and current after discharge and what time it will remain before earthing?

1919


list the type of vfd? wich is sutable for heating kiln?

2105


What is power factor why we should maintain the power factor unless what will happen

1918


What is the safety of UPS?

2044


How a band pass filter is constructed?

1070


how we can calculate 2 phase welding transformer rating or total power?

1878


Load transfer in 11kv double busbar switchgear - operation.

1959


What is ideal IR values for ground and neutral.

1761


what is the purpose of shading ring or shading coil in electrical equipments.

4480