present we are having 0.8pf but I want increase it up to
0.99 so what is the formula for it and how can i calculate?
Answer Posted / at
if you want to increase the power factor from 0.8 to 0.99
then in that case for
1. Generators:- you will have to increase the excitation
when generator is connected in an interconnected system
i.e. Many generators operating in parallel / or connected
to grid. increasing the excitation gives a leading power
factor and under excited generated draws lagging power
factor power.
2. When it is the case of Industries or other utilities
consuming electrical energy. one should know that all loads
consuming power are 99.99% inductive loads.Thus by adding a
capacitor bank of suitable rating shall be required to
compensate the lagging power factor.
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
what is distribution board?
What is dynamo?How it works and what is the function of dynamo in a DG.
In AC if the direction of current keeps reversing every half cycle, how does it propogate through the transmission lines?
Difference between ac parallel circuit and ac series circuit?
Explain the operation of variable frequency transformer?
What are the relays in ACB and VCB
in the case of 6.6kv motor starter combination contain fuses on it VCB. but in 11KV motor starter combination Fuses are not using in it's VCB why?
-What shall be short circuit current of LV switchgear for a 1000 kva, 11.415kv, 3 phase tranformer with 5% reactance.
why we r not earthed Control cable of C.T. terminals
what is meaning of sympathetic tripping with respect to relays and give the values for current carrying capacities for copper and aluminium cables from 16sq mm to 500sq mm
In how we connect watt meter for open & short circuit test of a single phase transformer.
why does a dc machine has high efficiency while working as a generator than as a motor ..
we have two generators different capacity on 15 MW and other 6MW at 11 KV , 15 MW gen. bus short level current 40KA,and 6MW short level current 25KA,, length of cable 100MTR between 6 MW from 15MW gen. for bus coupling . kindly tell any one can we use both NGR OR one NGR from any GEN. BOTH NGR has diff. rating. Tariq pakistan
How can we findout the maximum efficiancy of Transformer? At which load?
Define phase lag and phase lead?