Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why should we use Star-Delta connection in step down power
transformers?

Answer Posted / harishchandra

in Y the vL=1.73*vp
in delta vl=vp and current IL=1.73*ip
also for distribution required 230 n 433v so neutral is
required so we used y - delta conec.

Is This Answer Correct ?    23 Yes 7 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is meant by stator? What is meant by rotor?

1114


I have 1500/1A CT If i connect this CT in 6.6KV bus bar means what will be the voltage present in CT?

1994


Define noise?

1152


What is instrumental error?

1192


how to find the Motor,s insulation Power?

1754


we have amp, voltage, kw, length detail then how to calculte copper & alluminium size of conductor of 3-phase induction motor

1451


What is pd controller?

1102


how to generator maintenance (A Check, B check,Etc)

2292


I need to connect a synchronous generator to the grid using automatic synchronization and two circuit breakers (one for synchronization, one for end connection to the grid), how to determinate the required diameter of the cables?

2565


how to calculate the surge level of surge suppressors related to the SF6 cicuit breakers?

1961


specify the inbuilt protections in DG

2057


i am electrical and elctronics engg passed out in 2009 want to attend for reliance placements.plz send me apttitude ,technical and hr question answers to my mail plz. my mail id-kat.bindas@gmail.com

2016


Can I use distributon class/transmission class Lightning arresots for protecting the building? If not why please explain?

1942


Sir, My doubt on cable sizing calculation, Load:74 KW calculated cable 1 run 50mm2. Now client asking us to reduce cable size by increasing runs. Sir, My question now when my mind strikes with 2 options 1) Divide load 74/2 = 36 and calculate cable for 36+36 making it 2 runs or 2) Simply i can divide 50mm2 /2 ie. 2 runs of 25mm2 Please suggest me sir

1928


which is the best institute for PLC,SCADA,DCS in hyderabad

2345