Answer Posted / basavaraj patil
Buchholz relay is a gas- actuated relay installed in an oil-
immersed transformers for protection against
faults. It is used to gives an alarm in case of slow
developing faults or incipient faults in the transformer
and to disconnect the transformer from the supply in the
event of severe internal faults. It is installed in the
pipe between the conservator and main tank.
Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
how to calculate magnetic force genrated by a coil ?
How they LT panel busbar size choose
A powerplant has 8 gensets operating in grid parallel mode. In one genset sometimes there is pf variation and kvar variation. The plant operates in pf mode. When this variation is observed the load is stable, voltage is also stable, freq and genset speed is also stable. How will you check the functioning of pf card. What shall be the ideal output vdc of the pfc, from there it is input to AVR?
How to calculate KVA/VA rating of PT or CT from primary & secondary voltage or primary & secondary current?
How many kinds of E.L.C.B and how to work E.L.C.B
how we sesign the transformer give some specifion regarding design of transformers
What is different between resistance grounding system and resistance earthing system?
What is advantages of VSCF wind electrical system?
What is the requirement of grounding the neutral of single phase generators on load? If the neutral is not grounded, what will be the effect?
how invertor convert the dc into ac give brif detail
What is the formula to calculate the no load current of a single & three phase induction motor
what is V.L.F. testing of power cable? do you know the voltage ratings, like for what rating and size of cable what rating of V.L.F. testing is used?
what are the difference between PLC and embedded
What size cable (based on voltage drop) is required to supply a 40 A three phase boiler if the wiring system is 75V single insulated cables installed in non-metallic rigid conduit 56m from the main switchboard? Voltage drop in the consumer's mains is 8V.
When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<