Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Three set (each phase contain 2 cable of 400 mmsq CU XLPE
AWA) of single core cables are connected to 11 KV motor of
14 MW & the switch gear supplay is taken from 11kv feeder &
this supplay taken from 275 KV substation. Problem is one
pair cable(L3- 2 cable ) getting very hot & gland melted
and damaged in switch gear side. the other two cable
haven't any more hot(ambient temp only & L3 haveing 95- 100
Degree C. The same problem happened in 275 KV substation
switch gear side also where the supply taken for 11 kv
switch gear. But here L2 phese cable had problem. Why it is
happening like this?. The cable having temperature
different at different location from gland side inthe case
of 11KV feeder of 275 kv substation. why ?

Answer Posted / k.prakashchandra

This happens whenever there is a loose connection or under -
sized lugs are used.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how does high earth to neutral voltage affect electronic equipment?

1558


Either the Armoured Earthing strip of HT 3 core cable have to pass through CB CT or not , why ???

2091


what is the importance of earthing system on the generators big capacity and small?

1799


1.4 What is meant by CT knee point voltage and how would you determine it

1691


What is the difference between Delta & Wye windings?

2101


how many load we can take for lighting

2286


what is the function of capacitor duty contactor in an capacitor panel???

4152


If a transformer primary winding operates at 240v, the secondary at 120v and the load is 1500w & the transformer is rated at 92% efficient, what's the current flowing through the primary winding of the transformer? What is the formula for finding this?

2204


Is a d.c.compound motor is use as a booster? how?

2136


On what basis the the size of Lightning arrester for buildings are selected ?

1660


What is Meter MF if External CT Ratio is 150/1 , PT Ratio is 132/110 Meter CT Ratio is 200/1 & Meter PT Ratio is 110/1

1886


why electron produce magnetic field when it is in motion?

2153


What is super thermal power plant? and how it will differ from normal thermal power plant

2288


Do you know what is dry-out test in x'mer

2652


difrent between vcb acb sf6 and mccb breakers

5444