Which is is best option for 33 kv line incomer.I am
Desinging the panel for new projects and i would like to get
Your opinion on this
Vcb or sf6.
Please help me with your replies.
Thanks
D p singh
Answer Posted / sparta
VCB is better than than the SF6, because , VCB is compact
in size and required less maintance.
| Is This Answer Correct ? | 1 Yes | 3 No |
Post New Answer View All Answers
What is the difference between earthing,ground&nutral?
What are Contactors? How they works and what its highest rating?
what is the difference between elcb and rccb ?
How may I get the maximum current capacity for a particullar size Alluminum or Copper cable if there is compulsion to use?
Why do we need a separate control desk & PLC control panel in Boiler plant or coal handling plant? Can we provide cost effective Control desk cum PLC panel. Is there is an specific need for control desk.. kindly advice.
how to find out cable size if load is 2800 watts, 230 volts AC supply and load distance is 1800 meters
I have 2 KW electric water heater.I am gonna use it in controlling water temp.so I needed to increase or decrease the heating capacity.is there any electrical-electronic circuit for varying the resistance & so current?
WHat is the requirement of installing FAST ACTING EARTH SWITCH in GIS and how is that integrated with protection system. How and when does it operate?
what is capacitor voltage transformer?? how it is different from potential transformer?
Dear sir, In our plant have Station Transformer having capacity,i want to know, why LV side 40 - 40MVA is given? & how we can get 6.3 KV supply from tertiary(i.e. Open delta connection), Vector Group YNyn0 - yn0 +d MVA Rating 80MVA / 40 - 40MVA + 26.7MVA Voltage rating 420 (Tap range +6,to -10)81.25% /11.5KV - 11.5KV +6.3KV
what is the difference between "Rotary bypass isolation switch and Normal bypass switch" pls share indepth techs?
how to find 5 kilo meter long under ground 33 kv cable fault location if IR VALUE shows 0.05 M ohm @5000 volt.and cable fault locator shows some time fault distance 3 kilo meter ,3.7 kilo meter and some time 1 kilo meter? now how to find the fault location that where is leakage. note--it is tested with 5000 kv megger and insulation resistance is 0.05 M ohm. and some time 0.03 M ohm comes.
Can anybody post questions asked in Engineers India Limited Interview? Thanks in advance.
i need to give section engineer (electrical engineer) for RRB. Please suggest some book
What does the term power factor shows?