Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what would happen if u assume to insulate all the overhead
lines and no insulators....??do you think it to b an
advantag or a disadvantage??justify.

Answer Posted / shailesh tankni

Providing insulation to over head transmission line
would be beneficial, as it may provide more safety, and
comparatively the insulators used may be of small capacity
as required when uninsulated wire are used.
But the disadvantage would be that the it is not cost
effective as the transmission line is of large length and a
large amount of money will be required to insulate it and
also maintainance cost increases as the insulation may
deteriorate after a specific period of time.
And the complexity of sag calculation increases and
pole loading capacity required will also be high

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How does PLC work for sychronising of Two or more DG sets?

2131


where can i get vijaya electricals limited in hyderabad interview auestions can u give me the website address plz

2193


in dc series motor if field wdg is shorted then

1923


describe the phenomena of vacuum interruption in C.B

1848


how to minimize earth resistance upto 2Ω, if the resistance is 6 Ω ?

1883


What is the effect of positive feedback on the stability of the systems?

1140


Electromagnetic torque developed by the motor is compared to shaft torque. A less B same C depends on motor design D more

2097


Draw a circuit diagram in which if button is open we can use socket and bulb as a series test circit and if button is close than simple we can use socket as any load purpose.

1928


what is formula for calculate thermal overload in new numiricalrelay( not in bimetal relay)?

2370


DG cranking voltage?

4814


I am having a 1500 KVA transformer whose secondary current is 2086A and my connected load is 1000 KVA, I am having 400 KVAR APFCR for PF improvement what ratio of CT should i install in LT EB Bus to get optimum PF improvement?

1791


what is current check gurd relay?

2654


hello everybody. what does an abnormal stator winding impedance or dc resistance show? thanx

1968


1)how to reduce the value of tan delta of trasformer and CB,bushing,CT&PT,CVT ? 2)how to reduce the resistance of CB contact and its operating time? 3)plz.....send me the project report on conditioning and monitoring of substation equipment on my email id (gusaiyogendra03@gmail.com)

2370


What is the function of interposing current transformer?

1106