what are the effects on an power plant and consumers if the
power factor is increased or decreased?
Answer Posted / kirti
yes mr sushil you r right, increased p.f reduces current
consumption, but has no effect on frequency. please check
once and let me know if i'm wrng.
| Is This Answer Correct ? | 0 Yes | 1 No |
Post New Answer View All Answers
how did i get the competency certificate as electricle supervisor. iam completed my b.tech.but i dnt have any experince, this certificate is required for applyng ongc mangement trainees. what should i do sir please suggested me
What is the lockout relay
The inventer is a battery, but if lost current at home u will turn on the fan but the is AC and inventer battery is dc . Then how the fan was rotating. What device Or machine in fan converst the Dc power to Ac power
what causes contact chatter when there is no demand on the air conditioning unit?
what is the effect of vector group while phase sequence of a generator changes,whether the vector group changes or not
we have two generators different capacity on 15 MW and other 6MW at 11 KV , 15 MW gen. bus short level current 40KA,and 6MW short level current 25KA,, length of cable 100MTR between 6 MW from 15MW gen. for bus coupling . kindly tell any one can we use both NGR OR one NGR from any GEN. BOTH NGR has diff. rating. Tariq pakistan
why we use the 100% and 95% stator earth fault protection for the synchronus generator ?
What is the angle of inclination for the oil connection from transformer conservator to Bucholz relay and why?
can anybody tell me that for p.f. Improvment we use capacitor banks but how to decide its capacitance. As we all know how to calculate kvar but what abt capacitance value
What will happen if the voltage in my house drops from 220V to any lower voltage?
explain remenance . differentiate high remenance type ct & low remenance type ct
234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,
Explain cos(theta) and Sin(theta)
i installed 100kva ups. what KVA genset they should provid in input side? plz any update formula or ans with reason.
why the value of k is more in shell typr transformers?