Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

How did you conclude that when stressing a compond, all
degradation products have eluted in chromatogram?

Answer Posted / s.elumalai

The main aim of degradation study is to separate know
impurities in the case when we do not have know impurities
or to generate impurities from the sample by degradation.
Obviously one should know the process related impurities or
the degradation pathways. From peak purity by PDA or Mass
analysis one can conclude the purity of each peak eluting,
beyond that mass balance also account for peaks.If mass is
not balanced then one can conclude that some of the compound
are not eluted or may not have UV absorption.

Is This Answer Correct ?    7 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how to decide for one product require water content or LOD?

783


Why sometime potassium ortho phosphate mix with acetone use for sample preparation for hplc

1469


In HPLC calibration, caffeine is used as primary standard for wave length calibration due to caffeine is having dual maxima at 273 & 205 nm and one minima at 245 nm. Any body can give reference of these details from any pharmacopeia (with chapter no.) or any other authentic guideline?

1973


if you given one product then which tests you will perform?

709


UV and PDA detector, which have less signal to noise ratio?

1132


how a particular wavelength can be different for a particular compund while analysing by uv and by HPLC.

2301


why should we perform dissolution PVT calibration only by UV spectrometer, not by HPLC ?

1708


WHICH STANDARD WE USE IN SILICA ANALYSIS IN SILICA-GEL METHOD FOR SOLID SAMPLE

2132


which are the sizes of capsules?

971


Why we check moisture,ash & AIA in product

1885


Basic principle of ESI?

2151


Why to use propyl paraben in HPLC gradient calibration

7488


Which are the diffrent grades of api in pharma?

772


cefoperozone and sulbactam inj. hplc test method

2692


iam usig ph buffers merk. manually how to prepare ?

2278