Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

which motor is used in electric train...???????

Answer Posted / srikrishna

kongrates 2 all.. hu said dc series motor.

since the starting torque is very high, obviously this motor
is widely used for traction purposes..

the ratings of komn dc series mtr used for traction is,,

750v dc
650A
the gear ratio is 63:17
each locomotive (train engine)consists 6 such motors.
for more details on this topik kontakt me on mail id

Is This Answer Correct ?    45 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How harmonic block test are conducted on relays ( Siemens,Areva ect )power transformer using omicron kit?

2344


why does the magnetic balance tests at transformer?

1998


Graphs of measuring power and speed on dc motor

2022


why we use the 100% and 95% stator earth fault protection for the synchronus generator ?

2344


what will happen reduce the transformer voltage from 415v to 406v, is it save the energy,? are this methodis good to reduce the energy.?

1570


fuel-air ratio in a petrol engine fitted with suction carburettor,operating with dirty air filter as compared to clean filter will be

1112


in the case of 6.6kv motor starter combination contain fuses on it VCB. but in 11KV motor starter combination Fuses are not using in it's VCB why?

2344


HOW TO CALLICULATE RESITENCE,REACTANCE AND IMPEDENCE VOLTGE OF TRANSFORMER 13.33 KVA 144/240 VOLTS 93/56 A WITH FORMULA

2032


Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.

2176


How much pf maintan in dg set in 6o% load,when Dg runnig Neutaal Earthing removed what happen.

2040


what are the components in electrical control panel (for example: 415V, 3-ph, panel to operate utility and 3-ph DG set).

2078


What is Auto Mains Failure Panel & Auto Synchronizing Panel

1996


calculate external resistance values to add to the rotor of a slip ring induction motor. STATOR- 415 V, 3 phase delta, 1100 A, 50 Hz, 1490 rpm, pf 0,86 ROTOR - 660 V, 590 A, 50 Hz. STATOR current at each steps STEP1-600A,STEP2- 800A,STEP3-1000A,STEP4-1100A.

3624


how ups works ? various parts of ups and working principle

2073


what ispositive, negative, zero sequence impedence?

2081