two bolbs of 100w and 40w respectively connected in series
across a 230v supply.which bolb will glow bright and why?
Answer Posted / naresh kumar dhal
40 watt bulb.Because it has more voltage drop across it.
| Is This Answer Correct ? | 32 Yes | 14 No |
Post New Answer View All Answers
What will happened if the neutral of the (star connected secondry) Xformer disconnected? (if its Above KVA rated one)
what is the minimum (Common factor) insulatin resistance of the following a, 4mm sq wire b, cable from 50 mm sq to 800mm sq
How each of the following losses occur in d.c machines (i) copper (2)core (3) windage (4)friction please help me
In Power Line Communication (PLC) the wave trap is used to block communication signals from entering neighboring lines. My question is this: Why do they allow for different filtering arrangements on these wave traps? Isn't it always going to be a low pass filter since we want the power frequency to go through, and the comm signal blocked?
for hipot test on 33kV busbar, we will test on 70 kV or 56kV, what is the acceptable leackage current?
in non technical way how can u define POWER FACTOR??
howmany electrician should maintain for a 1000 kva used plant... in kerala..
What is the effect of solar radiation on the design of an Isolated Phase Busduct?
What are the material used for inductance coil?
If any HVDC line is going with positive & negative(the negative usually have return path of current with earthing electrode). Now the question is if this HVDC earthed electrode which is using as return path and earthed any nearby 400kv or 220kv AC substation equipments. which will be the impact of this on AC substation & its equipment, how severe may be this and what should be the minimum distance require between HVDC earthed electrode and AC substation equipments? It's really an high engineering level question...Dare to answer and increase your knowledge.
How select ELCB for 32amp. socket having quantity 12Nos. We have to do this wiring in PLANT. Please Also explain the incoming cable specification.
what is mean by restructuring power system?
Anybody know how schematic diagram for reverse power relay? RPR for generator protection
I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?
Is electro plating what type of load whether resistive, inductive or capacitive loads