Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

when motor taking high amp what happen.

Answer Posted / pillay

that means the motor is finding it harder to maintain
the speed. it could be due to so many reasons as already said
by DASS and VENKAT.
What happens is if any of the motor protective devices dont
trigger the motor to stop than it will continue to run
until the windings give way due to overheat and finally insulation breakdown which is commonly known as burnt.

Is This Answer Correct ?    3 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what's the difference between abs/inc encoders. apart from the position remembrance what are all the other differences. and what's mean by grey code.

2022


What is the requirement of grounding the neutral of single phase generators on load? If the neutral is not grounded, what will be the effect?

2062


why in a swquence network representation, the negetive sequence generated voltage is taken as zero?

1952


Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.

2081


How would you relate your key competencies to this position?

2159


A Question Like A Wire Is Wound Whose Resistance Is Some 132. 44647 Ohms. If A Voltage Of 30 mv, 296 Ma Current Is Applied To It What Is The Resistance.

1018


Minimum IR value of 1.1 kv grade 3.5c (300, 240,185,150,120,95,70,50,35,25) sqmm Aluminium XLPE cable and 4c (16, 10,6 & 4) sqmm cu arm cable between RY,YB,BR,RN,YN,BN,RE,YE,BE & NE.

3296


How PSV sizing being done

2263


how to changeover ups in this power failur time?

1931


how dia of wire and angles are calculated for overhead shielding wire to protect substation equipment from lightening strokes???

1981


how can found motors folt current ? how can disided circuit breakers caoicity and breaking capicity ?

2092


why fractional pitch winding generally used in alternators?

2894


what is the max. acceptable leakage current in 33kv bus bar

2945


how we decide scurt (disc) of insulator with respect to kv rating

3484


i need project topics along with circuit diagram in the electrical and electronics engg and also some websites regarding projets.

2028