Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the result of under frequency to the system.

Answer Posted / sivagurusgs

based on the V/F if frequency is less there is some
unbalance voltage flows through it(over flux occured) it
will cause the motor to run slowly and whenever unbalance
condition occurs the motor will take unbalance load so the
winding will be heated and thermal losses occur.s if v use
the relay to rectify this problem. Use overflux protection
for motor and overcome this fault. whenever frequency or
voltage gets unbalanced the relay will trip and isolate the
motor from the fault.

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

In the Variable Voltage Variable Frequency Drive, how the Voltage and Frequency varied ? Is it varied in the Inverter part of the Drive ? Please give us supporting document if any.

1945


In a Impedance Based Distance Relay (Quad Characteristics) - Could there be two different Line Angle(RCA) for Ph-Ph & Ph-Gnd? If So Kindly Let me Know.. Where, What are the advantages of the same?

1420


How does "OUT OF STEP" relay ,for Synchronous motor protection, work?

4339


Please explain, how to test vector group of tranformer(Delta y1) . Thank

1694


What is the lifetime of a Thyristor? Is there a recommended lifetime for thyristors after which they should be replaced?

2699


what is p.s impedance measurement test in earthing transformer?

2404


I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?

1860


what is the difference between rectifier and converter and commudator?

1940


what are the principles of a booster converter?

2064


How to do maintenance of transformer feeder.

1849


what are the interview question asked in wind mill about electrical

2362


What is non-minimum phase transfer function?

1295


Give idea about General Engineering. From which book i can study this topic. Pl. reply me via email. My email is ravi@bhelhwr.co.in, also give the name of book/website, from where i can prepare it.

2051


what are the differant std sizes of cable trenches?

2047


explain safety measures in alternator?

1779