Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the result of under frequency to the system.

Answer Posted / sivagurusgs

based on the V/F if frequency is less there is some
unbalance voltage flows through it(over flux occured) it
will cause the motor to run slowly and whenever unbalance
condition occurs the motor will take unbalance load so the
winding will be heated and thermal losses occur.s if v use
the relay to rectify this problem. Use overflux protection
for motor and overcome this fault. whenever frequency or
voltage gets unbalanced the relay will trip and isolate the
motor from the fault.

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what are the condition that makes hooter blow?

2368


iam preparing for rrb section engineer post in electrical branch.suggest the right textbook for my reference.fromwhere i will get the previous q.papers?

2207


The power supplied to a 33microF capacitor from a 120V, 60Hz source will be

2099


What shall be the secondary output voltage if the primary winding of a 220/6V, 50 Hz transformer is energized by an 110V, 60 Hz supply?

1296


why the NGR (neutral grounding resistor) always OFF during DG off?

3424


How to calculate total harmonic distortion level(THD) in VFD? and how can we reduce harmonics?

3999


how much winding resistance of 0.75kw to 12.5kw 3ph sqwiralcage induction motor?

2919


What are PLC leader logic program method

1706


How does a transformer contribute towards the widespread popularity of ac system over dc?

1053


15hp motor wound by 0.9mm & 0.95mm magnet wire. at no load test it draw 4.2A current. Another motor with same condition draw 9.2A current. How can that occur? pls help

1516


bus bar design conditions and sizing pls tell me quickly

1848


What is advantages of VSCF wind electrical system?

2278


in dc shunt motor if field winding is shorted then

1788


How to calculate or formula to calculate rhe power in 2 phase system ??

1448


FOR 16/20 MVA 132/33 KV ONAN/ONAF TYPE TRANSFORMER IT IS DESIGNED FOR 16 MVA WITH ONAN CONDITION.IT BECOMES 20 MVA UNDER ONAF CONDITION.LOAD LOSS IS GUARANTEED FOR 65KW AT 20 MVA AND % IMPEDANCE 13.75. PLEASE TELL US AT WHAT LOAD LOSS AND % IMPEDANCE IT SHOULD BE DESIGNED FOR 16 MVA AND WHAT WILL BE ITS EFFICIENCY AT 20 MVA?

3348