1) what is the seewage discharge per person per day taken
for design purpose as per IS codes? 2) how to convert gauge
to MM like if we measure 18G as our door frame then how
much is it in MM ? 3) how much binding wire is required ti
tie 100kg steel ? 4) while making rings in steel
reinforcement , whether the corners of rings are deducted
to take out cutting length ? 5) how much carbon content
should be there in steel used for construction purpose? 6)
what are fe415 & fe 500 and which bars are used in general
civil works?

Answer Posted / santosh singh

1) sewage discharge per person is 120 litres/day
2) 18 gauge = 1.210mm there is a chart i will be sending
you if u want just tell me your email id my email address
is santosh29civil@gmail.com
3) for 1 ton 9 to 13 kg of winding wire is required ie.
for 100kg you will need 1 kg winding wire approximately
4) no the cutting length of beam or column ring is
calculated by foll. formula
total cutting length of ring = 2( a + b )+ 24d

where a = long side of ring
b = short side of ring
d = diameter of bar
remember when a bar is bend by bar pipe the bar extends by
2d

5) not more than 5%
6)fe415 & fe500 are high yield tensile bars used in
construction also mils steel ie fe230 is used in
construction work.depending upon type of load & stress
designer chosses the types of bars ...ie fe415 & fe500 tor
bars are used as they are having high strengths

Is This Answer Correct ?    9 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what's the formula for calculate pcc for matt(45mm aggregate)?

2174


what is called the inverd level of mabhole chamber?

1644


what is density of 20mm coarse aggregate.plz send answer my below adress e.mail

1633


asubmerged weir is one in which the water level on the down stream side of the weir is just at the crest level below the crest level above the crest level at stamp elevation as water surface on upstream

1474


what is the water cement ratio for plastering

1177






In Residential home construct footing,beam, column,lintel,rcc roofs which dia rod used how to self assumed

2717


what is SDLC ?and write a 'c'program for to swapping the three numbers?

1407


what is diversion?

1760


PL.tell me about civil engineering questions with answer

2130


IN Compression testing machine 1division =10KN ,then what is compressive strength of 100*100 mm cubes at a load of 320 KN

1384


Design a reinforced concrete combined footing (rectangular) for two columns located 3.60 metres apart. The overall sizes of the columns are 40cm x 40cm and 69cm x 60cm and the loads on them are 1000 kn and 1500 kn respectively. The space available for the width of the footing is restricted to 180cm. The S.B.C. of the soil is 280 kn/mm2 use M15 concrete.

2196


Concrete cover for slab, column, beam and footing?

655


how much cement and sand required for 1cum rr masonry

4540


Doul Bar reinforcement and details of drawing.

1937


Basic questions of civil engineering

1628