what is the disadvantage of leading power factor...why can't
we use it (pf=0) for a long period of time?
Answer Posted / k.prakashchandra
In case of load,it will result in negative voltage
regulation increasing the voltage.In case of generators it
has the de-stablizing effect on the system ,the pf of which
is always lagging.
| Is This Answer Correct ? | 20 Yes | 2 No |
Post New Answer View All Answers
Explain difference between stand by earth fault and residual earth fault protection?
How to calculate the sag of OPGW during stringing???
Give details of your interested designation, the post you are interested to serve the company better and explain why you think you can serve the company better in such position if employed?
why the colour of insultor stack , petticoat is brown. Is it has some technical reason.
how we decide scurt (disc) of insulator with respect to kv rating
what will happen when the dc supply is given to the capacitor?
what's prime importance of protection in electrical system.if protection system don't work properly what can happen in electrical system?
While testing a ZCT what parameters have to check or measure?
In our factory so many iron pillors are exists for supporting the shed/Hangar. If do more no of earthings at one piller instead of doing more earth pits in many locations and running earth strip around the hanger, I can save the money. Please suggest this method is acceptable as per Is specifications though the Earth resitance of the farthest piller is with in the limits as per IS specifications.
how to select the automotive wire size by mathematical calculation. for xenon headlamp with ballast. the ballast given data voltage 10-17v,current permenant 6amp, run up phase is 15amp, peak at swicth on max 400micro sec is 40amp.the sum of cable resistance is 150mohm.please provide referenc document if any for relating the peak at switch on current,time & wire wire size
234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,
Draw the equivalent circuit of crystal oscillator?
sir i had plane to do some project with the base of hopkinson test in AC supply its possible
If we have to feed a housing complex having load 8MVA, than what would be the better option, either we first step down 33kv supply into 11kv & than 430v or we proposed no of 33/.44 kv transformer, also which option is economical?
How to calculate no of EARTH PIT? Describe the formula as per IS standard?