Answer Posted / jyoti sheoran
MODULATION IS A SCHEME WHICH ALTERS SOME CHARACTERISTICS OF
THE HIGH FREQUENCY CARRIER IN ACCORDANCE WITH THE LOW
FREQUENCY MESSAGE SIGNAL CALLED THE MODULATING SIGNAL.
THERE ARE THREE TYPES OF MODULATION :-
1). AMPLITUDE MODULATION(AM) :-
IN THIS TYPE OF MODULATION
FREQUENCY AND PHASE REMAINS SAME, ONLY THE AMPLITUDE
CHANGES.
2). FREQUENCY MODULATION(FM) :-
IN FM THE PEAK AMPLITUDE
AND PHASE REMAINS CONSTANT BUT AS THE AMPLITUDE OF THE
INFORMATION CHANGES, THE FREQUENCY OF THE CARRIER CHANGES
CORRSEPONDINGLY.
3). PHASE MODULATION(PM) :-
PM IS USED IN THE SAME SYSTEM
AS AN ALTERNATIVE TO FREQUENCY MODULATION. IN PHASE
MODULATION, THE PHASE OF THE CARRIER SIGNAL IS MODULATED TO
FOLLOW THE CHANGING VOLTAGE LEVEL OF THE MODULATING SIGNAL.
NEED FOR MODULATION :-
1: EFFICIENT RADIATION
2: FREQUENCY TRANSLATION
3: MULTIPLEXING
4: REDUCTION OF NOISE
| Is This Answer Correct ? | 7 Yes | 0 No |
Post New Answer View All Answers
when qty of cable being purchased is not sufficient according to the standard,what should the inspector do to ensure its quality according to the standard?
What is the loss of power of transformer 220kv/33kv,63/80mva of % imp12.05 at 80%load
what is meaning of 230volts ac 50hzs ac supply is it rms or maximum to getting ac 230v what amount of max voltage they will send
high voltage transformer input voltage,current and amps rating..distributed transformer input voltage,current and amps rating...
please give me all the Alarm .Trip ,Safety Relays & Conditions of UPS Systems mail me on ashokbabunhce@gmail.com
Dear all: Recently we got a question about Interface between PMS and SAP-PM.once we got a update message from PMS.we should set the deletional flag for functional location in SAP system.Is there any FM or BAPI to use?There are only functional location create and change provided by SAP. Best regards!
For small size, high frequency coils, the most common core material is- a. )Air b. )Ferrite c.) Powdered ion d.) Steel
what is the chemical name and formula of refrigarent R-134a.
How to assume answer to electrical questions
at work we have a 3 phase motor but on testing one phase isnt getting a reading. it runs 24 hours a day all week. stops and starts well no noise or heating. the phase isnt down to earth.is it just a bad meter reading or not? phases one and three came up with a resistance reading of 0.4 but phase 2 couldnt get anything shows up as open circuit.
Is there any type of starter for DC motor other than two point,Three point and Four point starters?
control & auxilary circuits used for circuir breakers
in electrical control panel. how can i choose the cable rating. (example - 11kw motor, 18-25A mpcb}
what is the difference between delta delta and star delta connection transformer? why we use delta delta transformer since it need earthing transformer for grounding?
i m electrical diploma holder i want to do plc $ Scada some body tell me which insitute is best for me near chandigarh