what is the difference between starter and control panel..?
Answer Posted / praful nandankar
starter is used to limit the starting current.As in case
of IM if it is directly switched to the supply,it will
draw 3% to 4% of full load current which is not suitable
for other equipments due to large voltage drop.
Control panel is for overall equipments and power systems.
| Is This Answer Correct ? | 4 Yes | 2 No |
Post New Answer View All Answers
On 400 amp factory load how kvarh capacitors provide
Explain in details how you would react to an unexpected incident when your supervisor or manager is not around to give instructions?
(1)The demand for electricity , the amount of renewable generation available, the amount of fossil fuel generation available and the cost of the fossil fuel generation are shown in table below period(hrs) demand(MW) renewable (MW) fossil- fuel(MW) cost of fossil fuel(MW) 00.00 - 01.00 2000 1800 2000 30 01.00 - 02.00 2300 2500 2000 30 02.00 - 03.00 2500 2700 2100 45 03.00 - 04.00 2900 3100 2100 50 04.00 - 05.00 2700 2600 2500 45 05.00 - 06.00 2400 2000 2700 50 06.00 - 07.00 2200 1800 2000 36 07.00 - 08.00 2100 1600 2000 36 Assuming that the renewable generation incurs zero cost, determine an optimal generation schedule(specifying the amount of renewable generation and fossil fuel generation used in each period, the cost for each period and the overall cost for 8 hours.)
Why Utility Distribution System in India is mainly at 11 kV? Why not Utility go for 33 kV?
what is the generator rating for 40 amp load of 3phase motor.?? 400v voltage of generator... plz tell me with formula its urgent...plzzz... and also tell me that this 40 amp at all phases mean 40 amp on red,40 amp on yellow,40 amp on blue...... or the total sum of that 3phase is 40 amp....
i applied for the ap transco please forward the freqventley asked QA
What is the maximum No. of out going mccbs permitted from an LV distribution paqnel? What is the ampere relation between incomer and out going switch gears/mccbs?
I need to connect a synchronous generator to the grid using automatic synchronization and two circuit breakers (one for synchronization, one for end connection to the grid), how to determinate the required diameter of the cables?
why Induction Generators are not "Black start" ? and apart from WTGs where this types of generator are generally used?
Advantages of using generator circuit breaker (GCB) scheme in a power station ?
can we make a electric generator,which can not use any type of fuel,air,solar,gas,thermal,coal,petrol,etc and able to produce electrical energy (or self electricity generating generator)
From past few months I am getting lagging pf even though sufficient capacitors used in circuit. Where is the problem pls answer
what is meant by 3rd hormonics ?
how many synchronous motor are there in any power plant
wish of these transformer uses oil?