If the damper winding on the rotor of a synchronous motor is
removed after starting what will happen?
Answer Posted / meenakshi
damper windings are mainly used to provide startn torque
for sync motors.though under the normal running
condition,the damper does not carry any current since the
rotor runs at a synchronous speed, it cannot b removed.its
another purpose is to prevent hunting(i.e,momentary speed
fluctuation) n helps the motor to run @ sync speed by
preventing oscillations.
| Is This Answer Correct ? | 31 Yes | 2 No |
Post New Answer View All Answers
What is transister define the transister ammiter ,base, colector.
what are the different methods for the starting of a synchronous motor.
What is the importance of earthing?
What is the function of electron gun assembly used in crt?
In ups static switch if i gives the supply at output end it will open the circuit in stactic switch or not if it will open then how it operates.
Block diagram of Power line communication?
how much winding resistance of 0.75kw to 12.5kw 3ph sqwiralcage induction motor?
If we have 11 kv RYB Phase single core cable near about. Then wht effect and losses
Define thermal resistance in the context of power amplifier.
STATE WORKING OF VACCUM CIRCUIT BRAKER?
Give idea about General Engineering. From which book i can study this topic. Pl. reply me via email. My email is ravi@bhelhwr.co.in, also give the name of book/website, from where i can prepare it.
What is the rating of circuit breaker needed for 300 KVA load in 33 KV supply line in a transformer of 33 KV / 415 Volt ?
TRAFO 1. WHY BREATHER IS USED. 2. WHY OIL GOES DOWN IN CONSERVATOR TANK. 3. WHY WE ARE TAKING OIL SAMPLE TAKING FROM BOTTOM OF TRANSFORMER. 4. HOW TO CHECK IR VALUE OF TRANSFORMER. 5. WHY OLTC HAVING BUCHHOLZ TRIP ONLY; WHY NO ALARM. 6. OFF LOAD TAP CHANGER OPERATION PROCEDURE. 7. TR. SHUTDOWN / ISOLATION PROCEDURE. 8. WHEN THREE TRS. IN PARALLEL, ONE TR. IS NOT SHARING THE LOAD – WHAT IS REASON AND WHAT YOU WILL DO. 9. WHY TR. HAS OLTC IN HV SIDE. 10. WHAT IS % IMPEDANCE. 11. WHY TR. RATING IN MVA. 12. WHAT IS VECTOR GROUP IN TR. 13. CONDITION FOR PARALLEL OPERATION OF TRS. 14. WHAT IS TERTIARY WINDING. WHERE IT WILL BE. 15. IF TR. TRIP ON BUCHHOLZ OR TAP CHANGER RELAY, WHAT YOU WILL DO. 16. DIFFERENCE BETWEEN OIL TEMP. AND WINDING TEMP. PROTECTION 17. HOW WINDING TEMP. IS MEASURED IN CAST RESIN TR. 18. DIFFERENT TYPES OF FAULTS IN TR. Trafo - Page-1 of 2 19. WHAT HAPPENS WHEN TR. CHARGED FROM LV. 20. WHAT WILL YOU DO IF MEGGER READING SHOWS ZERO BETWEEN LV WINDING AND EARTH. 21. CAN WE INTERCHANGE BUCHHOLZ RELAY OF MAIN TANK AND OLTC TANK. 22. IF THE LINE BETWEEN BREATHER AND CONSERVATOR TANK 23. LOCKED, WHAT WILL HAPPEN DURING LOAD CYCLE. 24. WHAT IS THE FUNCTION OF OIL SEAL IN BREATHER. 25. WHAT ARE LOCATIONS FOR BUCHHOLZ RELAY FIXED IN POWER TR. 26. WHAT ARE CHECKS IN POWER TR. DURING MAINTENANCE. 27. WHAT IS IMPORTANT WHEN WE CHECK OLTC OPERATION DURING MAINTENANCE. Trafo - Page 2 of 2
What is the power factor of a transformer at no load?
where are the circulat the diesel in DG parts name with pictue