What r the specification furnishid in motor name plate?
Answer Posted / ramendra shukla
The Following are specified-
1) Manufacturur Name
2) Sr. No.
3) Type of Motor-(AC/DC,1 or 3 phase induction or synch.)
4) Type of Connnection-(Y-Delta in case of 3 phase)
5) voltage,Current,Frequency(in Case of Ac)
6) Electrical Power (KW)
7) Mechanical Power (H.P.)horse power
8) Efficiency(in %)
9) Class of insulation- H,F, or C
10)RPM
11)Weight,etc.
| Is This Answer Correct ? | 4 Yes | 0 No |
Post New Answer View All Answers
which book to refer in electrical engineering for iocl exam & which book for general english.
how power is generated,and transmitted to our home..pls explain briefly in simple words.
what is the use of power transformer in GSS.
What is knee point voltage?
although ckt breakers have taken the place of old fuse. But instead of it , these older ones are still used in the industries and homes ? why .... what are their advantages and disadvantages ? which one is leading and winning the race and competition ?
please send previous exams question papers
what is the difference between earthing and unearth
As per the Anchor capstan motor specification, full load current is 200A. starting current is 1750 A and acceleration time is less than 8 seconds. Please guide for selection of cable size.
in a silicon diode we can measure .7v in a voltmeter.but why we can't use this voltage for using?
What are the advantages and disadvantages of closed-loop control system?
what are different types of electrical windings? i know the distributed winding ,concentrated winding etc but i want some detailed information, in what condition we will use distributed,concentrated windings what are the difference between them which is best, how induced emf changes by using different types of windings 20 hours ago - 1 week left to answer
how we can come to know that motor winding resistance which showing by DMM is right or wrong???is there any chart or something that we will compare & check???
What are the types of control system?
Pl. give me checklist for installation & commissioning of machine tool.
Why do we perform an open-circuit test and short-circuit test on the transformer?