Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why water, methanol, ethanol ets solvents are used in UV
SPECTRIPHOTOMETER for blank reading ?

Answer Posted / nabil

Methanol for example absorbs at wavelengths below nm, and
water below 190 nm if we use methanol-water mix as a blank
we would have to use a wavelength grater than 205 nm to
avoid false reading.

Is This Answer Correct ?    5 Yes 8 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

is it necessary to do HPLC calibration at wavelength 315nm if we are doing analysis at this wavelangth

2216


In performance Check of GC Why Hexadecane Peak is Considered 

3103


What is similarity factor and its use in api strength?

1363


if content uniformity passing but dissolution varrying then what is next step?

936


What is control room temperature and which guide line says?

1695


if you have given a blank water how you analyse by general analytical techniques?

2083


pharma industries oriented

2294


what are the guidelines for analytical method validations?

1149


What is similarity factor?

1260


can we use the same detector in HPLC as well GC and what could be the differences we can find in the final chromato graph in any aspects?

2224


I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?

3578


if you have given one product then how you determine the impurity in that?

800


What is importance of pH in the Heavy metal test and How it effect on the test results?

2325


why salisylic acid not using now days for disdolution calibration?

837


what is diffrence between specificity and selecivity?

836