Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What are the voltage values for LT,HT,EHT and other
voltages??

Answer Posted / raja

In India IS specifications are followed which has BS
standard as base.
Normally AC 50 V - 1000V volts are considered LT .
1kV to 66 kV is considered HT and
Above 66 kV is EHT
Voltages below 50 volts is considered Extra low tension

Is This Answer Correct ?    18 Yes 8 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

work of choke in florocent tube circuit ?

2128


It is desired to flood light the front of a building 42 meters wide and 16 meters hig.Projectors of 30 degree beam spread and 1000 watt lamps giving 20 lumen/watt are availabl.If the desired level of illumination is 75 lumen/m and show a suitable scheme.Assume the cofficient of utilization, deprecitation factor and waste light factor are 0.4, 13 and 1.2 respectively.

3864


Explain different types of d.c motors? Give their applications

1122


how to calculate vfd o/p voltage by frequency

2160


what questions will be asked for 11/33KV licence interview APSEB hyderabad. Can any one share question and answers.

18440


what is there inside an inverter and how it works?

1831


size of condotory fron voltage level

2209


i m doing DEEE in part time,can i join regular cources in BE,,IF i join what the cources can i select like (civil,ece,IT) ,,kindly advice

2104


What happen when change order of CT in GIS feeder?

1648


describe the phenomena of vacuum interruption in C.B

1772


What is fault clearing time for Current Limiting Moulded Case Circuit Breaker?.

1775


1)how to reduce the value of tan delta of trasformer and CB,bushing,CT&PT,CVT ? 2)how to reduce the resistance of CB contact and its operating time? 3)plz.....send me the project report on conditioning and monitoring of substation equipment on my email id (gusaiyogendra03@gmail.com)

2288


Why generation voltage in thermal power plant is between 11kv to 33kv?

1029


how to calculate the formula of cable size if motor kw is given

2265


List the disadvantages of constant k filters?

1660