At present how many HVDC lines are there in india

Answer Posted / gandhi pratik

at present in india there are three operating HVDC
transmission lines(not including B-to-B)

1)chandrapur to padghe(mumbai)--(1500 MW at ±500 kV DC)
2)rihand to delhi (dadri)(1500 MW at ±500 kV DC)
3)talchar to kolar (2500 MW)

and projects in progress are:
4)ballia to bhiwadi(2500 MW)-first pole charged as of 31st
March 2010
5)Mundra-Mohindergarh(Adani group-first Indian private
HVDC)-in progress,completion by 2011 end.
6)Bishwanath/Chariali to Agra(6000 MW)-recently awarded to
ABB-BHEL

Is This Answer Correct ?    20 Yes 13 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is differentila pilot supervision in the incomer control panel in the power station?

1631


What are differences between Voltage, EMF & Potential difference ?

1403


Why it need to form a capcitor when it not been in use from three or two year. Plz describe it technically.

1472


In single phase capacitor motor, if the motor rotate reverse direction then how much power will be consumed by the motor and why?

1478


What is the difference between multimeter

1459






show the single line diagram of star delta starter with single phase preventer

4112


What determines the thickness of the lamination or stamping?

1184


when ac current flows thru d coil of a contactr,it energizes,magnetic field attracts d contact of the coil...nw wont dt ac current in d contct induce current back on to d coil thru mutual inductance leading to high currnt in d coil

1273


What is the purpose of stablization resistor in high impedance bus bar protection

1538


how we arrange the hv side with delta connection in case 33/11kv of transformer.

1550


what is the working principle of energy saver control panel. please give the complete calculation & theory.

1837


any body,pls tell me how to done relay coordination ? how to coordinate by TCC curve?how to read the tcc curve?

1824


how to calculate magnetic force genrated by a coil ?

1739


Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.

1661


How you will determine the volume of oil in a particular Distribution transformer.

1445