Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

1,why we use 4-20 ma output of all instrument qhy not use 0-
20,
2,what is the different between PLC & DCS.
3,how can we meaure maximum span of new flowmeter if not
given any information.

Answer Posted / narendra mishra

suppose 0 to 20ma is used where 0 for
min.process value and 20 for max.then if
feed back cable get shorten or erthed or
broken it wil show min process value.where
in case of 4 to 20ma it will show "bad".

Plc are used to handle specific area where
DI DO signals are required like burner
managment system.plc response time is in
milisec. And that of dcs is in microsec.

Max span can be found by taking it online
and interfacing it with HART.

Is This Answer Correct ?    13 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to calculate mmwc values into tonnes?

1197


Where are oxygen analysers installed in cfbc boilers? What are their usual readings?

1482


How is automatic reference junction compensation carried out in temperature recorders?

1045


-/5A. What is the meaning and limitations of this in energy meter constant. It is a 3 phase LT Energy Meter. If this Energy Meter is connected through a CT of ratio 200/5 Amps, then what is the multiplying constant and how its will be calculated.

2375


What are the charcterstics of a P&ID controller block for Governor speed raise or lower for a load sharing functionality between 4 Gas turbines in droop mode.

2967


How we calculate orifice plat size???

1467


List three types Level Switches with their working principles

2065


the output of the common trasmitter protocol in qatar gas are the following

1954


when a magnet is heated?

1920


what are the definitions of input, output, command & signal according to instruments controlled by PLC using DCS System?

2061


Why the ammonia and Nitric Acid level indicators is with millimeter ? and What is the conversion form millimeters that level indicator indicate to weight ?

1752


why we are using magnet for calibration of gas detector?

2196


I was working on calibrating turbidity transmitters endress+hauser at effluent polishing plant.We calibrated using NTU buffers.What happened is that when we immersed the sensor, everytime we raise and lower the sensor gradually, the reading will vary.my question is that is there any specifications on what is the required distance from the bottom of the container with buffer to the face of the sensor?Is it ok to install the sensor in a medium which has turbulence specially if bubbles are present?

2138


how to calibrate corollaries (Mass flow meter)?

2109


What is 3 element control system

1439