Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

which is more dangerous A.c or D.C?

Answer Posted / ranjit burnwal

ac is the dangerous one at the same voltage.. most thinks
that ac permits u to go through 0V which give a chance to
relief.. but the human body is effected by the current not
by the voltage.. since an 220AC will deliver a much more
current than the 220DC so it is more dangerous..
few other thinks that ac gives u the chance to take your
hands off the current.. but this is also not right as the
needed reflection time(at least 0.3sec) is much more than an
AC current will provide you..

Is This Answer Correct ?    5 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How do i perform grounding of star point of Genset (400V) for making connection with step up transformer of DELTA-DELTA (400V to 20KV) ? while Genset itself has its own neutral and grounding bus bar inside genset breaker box whereas we have another neutral and grounding busbar in synchronizing panel next to genset at maximum distance of 6meter, would someone pls advice if we can only perform neutral grounding in synchronizing panel or should we ground neutral on both places inside genset breaker box and synchronizing panel.

1748


Why different Pressure switch used in marine boiler water circulation system

1770


howmany electrician should maintain for a 1000 kva used plant... in kerala..

2116


What will be the effect if I use inverter as UPS mood?

2205


WHY IN AC DRIVES,INPUT PHASE CURRENT SHOW UNBALANCE?

2304


Please explain me about Relay curves and their sources to read ?

1814


if grounding is notdone at regular intervals for long distance transmission, will the load connected at distribution end receive voltage during negativehalf cycle of the sine wave?

2038


How can you calculate the size of the down conductor cable for the lightning protection system. Is 70mm2 cable can replace 95mm 2 bare copper cable when the copper tape size is 25Wx3 thk mm.

5393


I want single line diagram for AMF & DG syncronizing panel

7200


why the carbon brushes are broken in srim while the motor runningtime

1722


What does the term power factor shows?

1132


single phase power supply give to separate one steel coup with water, what reaction create

2092


A mass of 1200g is accelerated at 200 cm/s2by a force. The value of the force required is:(a) 2.4N(b) 2400N(c) 240 kN(d) 0.24N

2977


what is the standard values(Megger test) of resistances between L&N,L&E and N&E for a system on IEE regulations?

2270


What is different type of Electrical curve and how it protects the equipment's while up-normal situation?

1821