Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

WHAT IS THE SIGNIFICANCE OF VECTOR GROUPS IN TRANSFORMER?
WHAT WILL BE EFFECT WHEN PHASE DISPLACEMENT CHANGES IN
TRANSFORMER?

Answer Posted / sunil ulange hit nidasoshi

Vector Groups are made especially to make out difference in
the connections. The connection can be delta(D) or star(Y)

The primary winding connection always denoted by Capital
Letter (D), and secondary winding connection always denoted
as small letter (y), and neutral n

The number after that indicates the phase difference
between the primary and the secondary voltage.

e.g.-> DYn11 means transformer is star connected with
secondary voltage leading the delta connected primary
voltage by 30 degrees.

normally distribution transformers are have Dyn11 connection
because secondary of transformer are connected to at user
end means motors,inductive load etc,

These loads always havelagging Power factor thatswhy Dyn11
connected transformer means secondary volatage leads by
primry voltage by 30 degrees, hence Power factor maintened
constant.

In Clock 11 indicates angle between 12 & 11 is 30 degrees
i.e. 360/12=30 degree

Sunil ulange
Application Engineer
Southern power equpment Limited bangalore

any Questions @ sunil_031@yahoo.com

Is This Answer Correct ?    16 Yes 11 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

If oil and air can withstand a high MeV when used as an insulator in a transformer, what are the values of how high for each material?

1963


types of central Air conditioner plant?

2209


difference between the applicability of nortons and thevenin theorem

2132


How to calculate the input cable rating for 10kva ups (3phase input and single phase output and also 3phase output, battery rating 65Ah)provide the formula also.thnx

2290


Why do we perform an open-circuit test and short-circuit test on the transformer?

1173


What facility we get after CT secondary earthing and how?

2294


dg earth connect only in the amf panel or not why

2139


why the difference arise between HT reading & LT reading (submeters fixed in complexes, apartments etc)if the power factos exceed from 0.9 to 1 can the ht meter reads fast?

3028


How can calculate the rating of a servo stabilizer for given a specific load

3568


What are the advantages and disadvantages of the ac motors?

1194


how you will decide the distance between the power transformer and its fencing

2004


How could a garment factory benefit from renewable energy

2822


when ID fan will immediately stop through VFD what exactly cause and problem the ID fan

1516


I have a situation to design sub-Distribution board/Panel meant for feeding power sockets. In the incomer CAN i Take TP MCCB with Neutral Link and All the outgoing feeders with to sockets with TP MCCB and Neutral Link? P.S : My System is IT Earthing

1875


How generator NPS(NEGATIVE PHASE SEQUENCE TEST)TEST WAS DONE? PROCEDURE WITH DETAILS?

2281