Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What should be the DC voltage for Hi-pot test on 11kv switchgear

Answer Posted / solanki

i think it will be the around 23 kv for the 11 kv switchgear
bcz its take the calculation twice of rated switchgear voltage

Is This Answer Correct ?    4 Yes 9 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

why we can stote dc? why we cant store ac?

2068


What is mathematical model of a control system?

1138


Good day everyone,currently in our premise we using 30kw slip ring motor with resistance bank which we use as forward and reverse at conveyor bar handling. So,my question is how do we calculate the resistance bank which is suit the motor. Kindly,assist me... thank you

1712


please I wont know how to calculate the vector group for power transformer ZNyn11 best regard.

1840


why the protection turbo generators is most complex?

2035


what is the calculation involved to design the heater to heat 10KL of water in temperature control unit?

1925


How to calculate earth wire load by formula

2576


What is the formula to calculate a three phase alternator

2327


PLZ EXPLIN ABOUT CLASS PS CLASS CT .WHY THEY R DESINED AND FOR WHAT PURPOSE?WHY OTHER CT CANT BE USED AS PS CLASS CT? EXPLAIN IN SIMPLE LAUNGAGE IF POSSIBLE PLZ GIVE CIRCIT DIAGRAM?EMAIL-RAJ_SINGH_0376@SIFY.COM

2260


Why frame of the motor is specified?. If we mention KW and voltage level,automatically frame is decided or separately frame is compulsory to mention?.

1726


I Have 3 Phase 10 KW AC Alternator i found one phase weak, so what will be the reason & what action shouls i take to rectify the same.

2061


any application of back emf

2115


what is the diference between the 4pole & 6pole DC Motors & what is advantage 6pole over the 4pole ?

1998


what is high - pot test. what's its use?????

2179


Can anyone please give me the parameters , formula needed to calculate the circuit breakers for building services.Thanks

2125