1 ton AC takes how much current( starting & stable)
Answer Posted / nikunj
1 TR = 3.51 kw
Now as per formula, P = V x I x COSphi,
I = P / (V x COSphi) for single phase,
I= P / (1.73 x V x COSphi) for three phase, so you can
easily calculate the current rating required.
| Is This Answer Correct ? | 17 Yes | 26 No |
Post New Answer View All Answers
I need model question papers for RRB section engineer Chennai... Please send to my E-mail Id:- maitheerainbow@gmail.com
What is the effect of positive feedback on the stability of the systems?
what is the importance of earthing system on the generators big capacity and small?
I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?
how to find impedance , mutual indatnce in transmission lines
Starting current of a 10 HP induction Motor is ______ time’s full load current.
Explain how to determine capacitor tolerance codes?
How to calibrate or test an LT Air Circuit breaker 440 volts, 35 KA, 800 Amps ?
I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?
DRAW ACIRCUIT DIAGRAM OF 100 KVA 415V/55-0-55V DELTA TO STAR TRANSFORMER
Name one of major transformer company in KSA ?
when we gave dc supply to 220v dc motor its rpm is 1200. then we gave 180v. how many rpm of its motor. gave answer with calculation at my ID.... ravizak@ymail.com
in general it is observed in power stations, the tertiary winding is used in higher rating Y-Y auto transformer but not in Y-Y power transformer. is the tertiary winding is compulsory then why it is not using in power transformer
Is it required to do earthing in 2nd shop if earthed armoured cable is laid from 1st shop ?
i have flexible wire. size of conductors is 0.190 mm & no.of conductors are 48. then size of wire comes 1.37 sqmm instead of 1.5 sqmm . the what is tolerance for this size.