why the rating of transformer in only KVA not in others?
Answer Posted / naren
transformer having two kind losses .core losses and copper
losses . former depend on voltage while latter on current
so that why transformer rating is in KVA .
| Is This Answer Correct ? | 14 Yes | 6 No |
Post New Answer View All Answers
what is earth-fault?when it occurs? to check where it occurs what type of test should we do?
what is the best transformer oil breakdown voltage?
Dear Mr B C pal...Can you plz. put some light on principle of operation of Z-Ct in conjunction to its use with 1Cx1000Sqmm HT Cables & Directional Ground Fault / Over Voltage Relays...Regd..Parag v K 9899115632
mostly the questions were from machines... d.c. machines, transformer, synchronous and induction all theory paper........ few from power system... but the level of paper was easy.....
A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.
Hi Friend I am used multimeter to measure the voltage between R Phase(SS1) to R Phase(SS2). In SS1 is connected with UPS loads. But I am getting voltage between these 2 R Phases. Please give some idea friend
On a 6 KVA UPS we have to provide a DC MCB for Battery bank of 16 nos (12 V 42 AH). What Shall be the current rating of DC MCB ?
What is rotary phase converter?
what is the maximum permissible limit value of leakage current and leakage counter reading to replace lightining arrester?
How the over load setting for HT Motors calculated-provided in Numerical Relay
A cotter joint is generally used to transmit
how to determine ct ratio in ht vcb?
A low wet bulb temperature indicates
1.why are not using acb 33kv ht side? is there any problem 2.what is difference between acb,vcb,sf6 breackers? 3.what is the function of invertor and convertor in ups?
what is meant by twilight switches 7 where its applicable ?