Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is PF? Formula for calculating PF in HT side?

Answer Posted / hari

The cosine angle between voltage and current vectors is called a power factor.


power factor = active power/apparent power.

Note:The power factor is depending up on reactive power. so it is not need on(special) HT side.

Is This Answer Correct ?    8 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Explain The Application Of Storage Batteries?

1151


Why we use circular(Stepped) cross section in transformer core?

2251


What is the difference between PLC and Embeded system

1432


typically in power distribution substation. 1- Any idea how would be the graph of capacitor bank consumption verses time through the day . 2- How is the switching ( on and off ) of the capacitor bank, per need?

1735


Why is the air gap between the pole pieces and the armature kept very small?

1401


please tell me when we start motor without load in star or delta connection whose current above condition,pl write formula

2293


What is power factor why we should maintain the power factor unless what will happen

1917


33kv Rated output avilable in market (any where in india)

2076


Good day everyone,currently in our premise we using 30kw slip ring motor with resistance bank which we use as forward and reverse at conveyor bar handling. So,my question is how do we calculate the resistance bank which is suit the motor. Kindly,assist me... thank you

1719


can mini-curcuit supply MIL-tested transformer !

2136


What is touch potential and step potential?

2160


for hipot test on 33kV busbar, we will test on 70 kV or 56kV, what is the acceptable leackage current?

1167


What are the different types of dams?

1237


if an insulated power and control cables of a running gas diesel gensets laid direct in an open trench i.e, trench bed is not rcc of a power house in which rain water, spillage water alwas exists and all power control cables remains submerged even when gas gensets of 480 kw each runningin on load. These power &control cables runs from power house to switchgear room through these trenches in which water remains most of the time. pl explain its merit & de-merit

1879


Is it acceptable of installing an earth pit in planters area where bare copper cable, earth rod and connection are susceptible to corrosion due to water?

1960