in our transmisison sub station why we step down firstly
132kv\33kv then 33kv to 11kv. can we direct step down 132kv
to 11kv.
Answer Posted / gudsam
WE USUALLY FOLLOW THE SYSTEM OF TRANSMISSION OF TWO TYPES.
FIRST, WE STEP DOWN HIGHER VOLTAGES TO SLIGHTLY LOWER ONE TO
DISTRIBUTE SOME INDUSTRIES OR BIG CONSUMERS INCLUDING THE
LINE LOSSES. THEN WE USE THEM TO TRANS MITE TO DOMESTIC
PURPOSE. SO THEY KEEP THEIR VOLTAGE LEVEL HIGHER AS THERE IS
A HUGH AMOUNT OF LINE LOSSES IN THE TRANSMISSION LINE.
THAT'S WHY THEY SET DOWN FIRST AND THEN TO LOWER ONE.
Is This Answer Correct ? | 9 Yes | 2 No |
Post New Answer View All Answers
what is proper capacitor placement? How to evaluate capacitor size?
what are the disadvantages in GIS over AIS
Does all the output contacts (N/O as well as N/C) of a Numerical relay operate when relay receives a binary input/inputs or contacts are designated to specific logic input/inputs and only these contacts operate?
Can any body tell me the different types of LT cables & their application.
Can any one give an explanation about rating factors of cable? if we are laying the cable on the air with an temp 15 degree then rating factors will be 1.15 and if we are laying the cable on the air an temp 60 degree then rating factor will be 0.76 please describe it and what is the difference between rating factor and derating factor?
Please elaborate th´evenin’s theorem?
why should the lowest unit of a testing transformer ( cascaded transformer ) have higher power rating??
in the directional overcurrent and earthfault protection,normally we are setting the angle 45 deg lead for phase fault overcurrent and -45 deg lead for earthfault fro forward direction.but both the fault are operating on the same angle region only.why?how the relay will response?
need to make a report. Need to choose a 3phase induction motor. Load conditions motor will operate in : Maximum Load: 30 Kw Speed: 2950 rpm Ambient temp: 20 cent Supply voltage: 440V Frequency: 50Hz need to look for the safety factor when choosing the motor, went through catalouge found a few, but dont know how to choose the safety factor allowing an extra load something above 30 KW to avoid any harm.
transformer spections :: input voltage 0-110-230v; output volage 0-10-12-14v; amp=3A using CRNO CORE, capcaity=50VA primary turns = ? ; secondry turns =?
explain different types of d.c motors?
What will happen if the d.c. Machine is operated below rated speed?
CBCT selection
what is the use of Auto re-closer?
Explain about c.t?