a 3 phase slip ring induction motor is wound for 4 poles on
stator and 6 poles on rotor; when 3 phase balanced voltage
source at 50 hz is applied to motor it will run at
a)1500rpm b)1000rpm c)750 rpm d)zero rpm
Answer Posted / a.sakthi
answer b) 1000 rpm is correct. because 120f/p =N.here N is
the speed of the motor. hence f and p is the input frequency
and no of poles on the stator or rotor respectively
(depending upon which one is the rotating portion of the
motor) so and so, in general rotor is rotating so the answer
b) is correct. if the stator is rotating, answer b) is correct.
thank you....
| Is This Answer Correct ? | 7 Yes | 2 No |
Post New Answer View All Answers
i have been tasked with a design of protection, metering and control(PMC) relay panel extension to accommodate all PMC relays.There is an already existing panel where this one will be built.What are the design aspects for this kind of project? thank you.
Importance of fault current in power transformers and how to monitor the same? How is it different from winding temperature?
please write motor, transformer, Generator setting, fault level calculation of Tr.etc
How to calculate earth wire load by formula
How to design inductive load for 3 phase 440v and maximum 5 amps for star or delta? Can we use a 15kW, 1450rpm motor for 15kW, 960rpm apllication?If yes.how......n.if thesame motor used what`s it`s sideeefect.
May I know how much values to be set for earth fault, over current and short circuit values at 11kv side? I have 11kv van 1250amps rating. Present it's taking load 80amps?
I WANT TO know WHICH WAY IS BETTER FOR CONNECTION BETWEEN POWER TRANSFORMER AND MAIN DISTRIBUTION PANEL. 1-IS BETTER WE USE CABLE? 2-IS BETTER WE USE BUS DUCT? my transformer rate power is 2500KVA
I have a current transformer with 1 main reading meter with transformer outside the building and a control panel having 5 CT reading meters with black round coils inside the building. I want to know, A) when current pass through the Transformers, will the current be reduced or be the same and after that B) when current pass through the CT meters with black round coils, will the current be reduced or be the same. C) in the above process will the reading of the main meter be same or different, from the total reading of all the 5 CT meters.
How can we find the breaking capacity of a Load breaker switch (LBS) fed from 11 kv supply??ex:50KA, 26kA etc???detailed step vice answer pls.
what is effect of 5amp fuse on 2mva pry protection of transformer
hi frenz,its aswathy.i hve aplied for the hpcl test on feb,pls send the test patern & the placement papers as soon as possible. mail-id :kjaswathy@gmail.com
What is T’Q and X’Q and X’D ? and what is saturated as well as unsaturated ?
why various test are performed on electrical panels & power cables before commissioning on site & what are these test???
Why Water motor is not taking a load or pressure while everything is correct. (Note: Motor running properly)
formula for calculation of switchgears(i.e. contactor, fuse, cb, relay etc.), if load current is given?