Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what type of protection used below 132KV feeders

Answer Posted / p.mahesh goud

1.over current protection
2.earth falth protection
3.Distance protection
4.shart circuit protection

Is This Answer Correct ?    4 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how much allowable resistance that can be difference in motor all coils?

2416


Explain the construction of the conservator, operation and purpose, and draw the diagram of the conservator.

2560


hi friends if you have any 400KV Substation Erection and installations Drgs please send to me.My email id:kandi.suresh441@gmail.com

2973


how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING)IO (current operating

2469


Can we put 3 layers of cable tray while installing tray

2454


Define step response?

1253


What is the suitable transmission voltage?

1118


What is the relationship between voltage,current & frequency?

1827


What is icu and ics in Acb and how many time icu or ics passes from breaker?

1609


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2201


can i connect wavetrap in 2 different phase in EHV line?

1924


What is the voltage gain or transfer function of amplifier?

1183


what are inductive and capacitive voltage transformers.what are their applications

2009


Which is the oldest hydropower plant in india?

1216


What is the ratio of true power to apparent power in an ac circuit?

1192