Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is difference between GC & GC-HS

Answer Posted / kuchela rao athota neuland lab

GC-IT IS ANALYSED LIQUID SAMPLES ONLY
GC-HS:-IT IS ANALYSED LIQUID AND SOLID SAMPLE S ALSO
IT IS DONE OVI(ORGANIC VOLATILE IMPURITIES)

Is This Answer Correct ?    9 Yes 30 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How we can identify process related and degradation impurity in single method with short period?

808


I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?

3534


What is related substance by HPLC impurity limits as per USP?

1098


What is column in chromatography?

2233


How do we get end points and how many end points are possible for citric acid and di-acid not theorotically answer should be given practically.

2580


why require to add enzymes in capsules dissolution only? is it require to tablet also?

679


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1592


if content uniformity passing but dissolution varrying then what is next step?

867


How they found 1mL of K.F reagent is equivalent to 5mg of water and if we change the composition of K.F reagent, is it can neutralize more amount of water?

1771


Difference between hlaf and rlaf

2105


how you confirm the assay method?

764


Which parameter require to do for analytical method equivalency?

770


If we do accuracy at same concentration at which linearity planned,what is the need to do linearity separately?

2296


What is the principle of Thermal conductivity detector and FID?

2724


all types of questions asked at the cipla interview

4676