why rating of transformer is in KVA but of motor is in KW
Answer Posted / krish
A = Appearing as a first letter denotes Aluminium Conductor.
Y = TROPODUR (PVC) Insulation or TROPODUR (PVC) Sheath
depending on the position in which it appears.
2X = TROPOTHEN-X (Cross-linked Polyethylene) Insulation.
W = Round Steel Wire Armouring.
WW = Double Round Steel Wire Armouring.
F = Formed Steel Wire (Strip) Armouring.
FF = Double Formed Steel Wire (Strip) Armouring.
C = Metallic Screening (Usually of Copper).
CE = Metallic Screening (usually of Copper) over each
individual core.
Gb = Holding Helix Tape (of Steel)
Wa = Aluminum Round Wire & Aluminum Formed Wire (Strip) Fa
Armoring
| Is This Answer Correct ? | 1 Yes | 14 No |
Post New Answer View All Answers
IN SINGLE PH TRANSFORMER IF LEKAGE IMPEDANCE DROP IS NEGLECTED ,THE FLUX IN THE MAGNETIC CORE and the lekage flux linking a winding are a)proportional to the applied v to the winding i respectively.
what is automatic voltage regulator?we can control the vlotage by using fuzzy controller in matlab?why we go for fuzzy?
what is the main parts of transformer? how it is functioning? pls giv the ans briefly.
1. A bomber drops a bomb from an aircraft flying at 2000 km/hr. at an altitude of 7km. The speed at which the bomb will strike the earth would be
how to select battery for 15 KVA UPS with formula
Why i receive the GCU fault in my DG Sychronization panel . what all the factors considered for this fault .
In hydel power plants, L.A's, S.C's are placed inside the control panel boards. what is the purpose? [already the total body was earthed to ground.]
need to make a report. Need to choose a 3phase induction motor. Load conditions motor will operate in : Maximum Load: 30 Kw Speed: 2950 rpm Ambient temp: 20 cent Supply voltage: 440V Frequency: 50Hz need to look for the safety factor when choosing the motor, went through catalouge found a few, but dont know how to choose the safety factor allowing an extra load something above 30 KW to avoid any harm.
When will you multiply and devide with derating factors to the actual value while sizing the cable?
how to check ac servo motor
How much costly in percentage wise is sandwich busduct costly than air insulated busduct of any rating?
WHAT IS START TO INDUCTION MOTER IN STAR TO DELTA OF >5HP ?
Why power genaration in India is at 50HZ while America its 60HZ
how to calculate
The metal-enclosed switchgear and controlgear is subdivided into three types: 1. metal-clad switchgear and controlgear; 2. compartmented switchgear and controlgear 3. cubicle switchgear and controlgear. What is the main differnence between them. State some example.