Answer Posted / ajay singh bika
In GSS there is high fault current flows to the earth so
that there may be a potental difference due to this at
ground..... so if a person stands at the surface of a
substation he can get shocked due to this potential
difference so by this mesh earthing the potential can be
spread out whole the substation surface and this surface
become equipotential.
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
does a DG set has low fault level as compared to that of a transformer.If yes then why.
What is dynamo?How it works and what is the function of dynamo in a DG.
we have require a Motor (1500kW, 6.6kV, 50Hz) which shall operate at 1500rpm during 30min and after it shall run on 500rpm during 15min. The same cycle shall be repetitive during the whole working days. Which method is best and economic to achieve such type of task. VFD, VVFD, Pole changing motor etc.
why capacitive load is not used in routine life????any reason is there ??????
What is the Temperature to be set in Thermostat provided in Marshalling box of the Transformer / Motor.
What kind of maintenance is conducted for Transformer
hi can any body send me syllabus of rrb electrical section engg... and past pepar also of any board...
why we are not giving the zone 1 trip command to the master trip relay
234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,
Define demand factor?
What happens if the Capacitive Voltage Transformer Primary neutral is not earthed. There is a CVT between Transformer and source, and the CVT neutral of the transformer is not earthed, does it effect the transformer while charging or does it effect the transformer charging process.
Please help me regarding my one concern. - During earth pit testing we noticed that the Clean earth pit and dirty earth pit showing continuity (Resistance value - 5ohm) . I want to know that if both earth pit have separate location and there is not internal looping between PIT then why such continuity is showing on it . Because of this issue the field side all earthing point showing short. In PLC panel we are providing two types of earthing cable which is coming from separate earth pit (Clean and Dirty earth pit) because of earth PIT showing short our PLC is not complying spec . please help regarding this issues.
what is through fault?
why we dont prefer ac voltage controller instead dimmerstat [if both have same rating] for conducting experiments in laboratories?
Draw a 230kv two-bus bar system showing the following. 1.Two generators (150MW) each connected through one 15.75/230KV transformers 2. 1 outgoing lines 3. Two 230/130 KV transformers 4. BUS PT's 5. CT