Why TAP changer provided in primary side of HT
transformer ? and why not in secondary?
Answer Posted / ram sumer
This depends on your use,for which perpose transformer is
been used. If the transformer is usde for long distance
transmission line i mean in delta to delta HT transformer
tap changer will be provided on primary side. To cover the
line losses which make a cause of voltage drop,when primary
side tap is changed in ratio of that tap position secondary
will also increase or decrease the voltage as you desire.If
you provide it on secondary side it will oppose the primary
voltage
But in case of distibution transformer i mean delta to star
tap changer is provided at secondary side.
| Is This Answer Correct ? | 4 Yes | 14 No |
Post New Answer View All Answers
What is power distribution criteria for converting single phase unbalanced residential load to 3 phase star connected balance system. Does total KW converted to 3 Phase. Means Divided by root 3.
What is difference between insulating medium and fault current interruption medium in a switching device.
what is the difference between the characteristics of two different phase bushing of any transformer
How can we convert 11 kv to 440 volt without using transformer ?
can you any one give exact mathematical relation between AC current and DC current?
how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING)IO (current operating)?
When is lag lead compensator is required?
why only exciting current is shown not primary current in transformer???
how to calculate the earth fault current
What is the difference between a verilog task and verilog function?
IF DISTANCE IS 100METERS B/W AMP.METER AND CURRENT TRANSFORMER WHAT WILL BE AFFECT IN ACCURACY .METER CAN SHOWING ACCURATE CURRENT OR NOT IF NOT WHAT CAN I DO TO GET 100% ACCURACY.
hi frenz,its aswathy.i hve aplied for the hpcl test on feb,pls send the test patern & the placement papers as soon as possible. mail-id :kjaswathy@gmail.com
234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,
You are of electrical field and you are going for software? Why
i am studying in final year can i allowed for 23rd UES of Indian army