Answer Posted / m.senthil kumar.areva
power factor is the cosine of the angle between voltage and
current.....maintaining of power factor is essential thing
for improving the power factor capacitive load to be added
on the circuit for decreasing thee power factor inductive
load to be added on the circuit......
| Is This Answer Correct ? | 12 Yes | 2 No |
Post New Answer View All Answers
why should small green grass ans small plant should not be there inside the transformer Yard in the factories
How to know of any cable size if there are not written on cabl?
What is meant by rotor?
Can anyone please give me the parameters , formula needed to calculate the circuit breakers for building services.Thanks
How to back charge the Gas turbine generator
i am venkat i got gre 930(verbal 270 quanta 660) and my toefl score 105..here question is why u got less score in gre ? what i supposed to tell...any chance of rejection is there...my accadamics record is very good
what is the main parts of transformer? how it is functioning? pls giv the ans briefly.
what are the breakdown voltage rating of mini- curcuit'transfarmer!
What are the components connected in between the power supply coming from an electric pole to HT & LT Panels in a large commercial building or how the power supply connected from Electric pole to Transformer & then to the HT & LT panels of a building? Please send me answers via mail, my id is yogiagarwal@gmail.com. If possible, please give a line diagram.
What is process of anneling transformer core
can we use NPT glands in LT panel
Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.
In power transmission using open belts or horizontal shafts it is preferable to have the slack side of the belt on the top because
what is the difference between the characteristics of two different phase bushing of any transformer
What are the two segments of nyquist contour.