pleasee tell me the risks and hazards of a Cable Jointer
job? Thank you.
Answer Posted / mohammed amjath
As a cable jointer he should follow the safety first.A
jointer should use the measurement drawings in the
jointingkit.if he is not using it may cause shortage of
cable.Improper crimping will cause failure of cable
joints.Then the goverment authority will cancel the licence
of the jointer.A good jointer will first do meggering of
cable,Proper mesurement,And good crimpping.
| Is This Answer Correct ? | 10 Yes | 0 No |
Post New Answer View All Answers
what would happen if reactive power (kvar)is increased (more)or decreased (less)? how much exact reactive power should be maintained? and what should be done for that
why impedance relay is used for medium transmission line protection
How one may guess the direction from which the distribution line is incoming if there is no pole plate on poles?
I want to know the 'Test voltage' for Tandelta testing of 3.3 / 6.6 / 11 KV Motors. Please explain
kVA rating of ordinary transformer is increased when connected as an auto transformer because A transformation ratio increased B secondary voltage increased C energy is transferred both inductively and conductively D secondary current increased
WE know that for Inductor X=2pifL,In DC f=0,then X=0 so,V=IX=0;But In the DC excitation of rotor of AC generator,DC motor field coil which coils are inductor so why does not applying DC voltage short the rotor coil of AC generator and field coil of motor?If it would then DC source might be damaged but it is not happened. Why does the strand conductor of Electrical power transmission line make twist?
What is the Basic Difference bitween Long Shunt Connection and Short Shunt Connection in DC Generator?
What are electric motors?
transformer spections :: input voltage 0-110-230v; output volage 0-10-12-14v; amp=3A using CRNO CORE, capcaity=50VA primary turns = ? ; secondry turns =?
Dears we deal in Chemical are Plate earthing. Kindly call if any requirement and questions. Tech Earth Solutions Mohit Verma 8791071007
How the circuit breaker is selected for Induction motor of 100 kW, 415 volt, 0.85 power factor, 0.95 efficiency ?
All the socket in a room become very hot, the Wall was also became very hot and the earth conductor also became live, what in your view might be the possible causes?
why ahould you show client/engineer activities clearly on the project plan
May I know how much values to be set for earth fault, over current and short circuit values at 11kv side? I have 11kv van 1250amps rating. Present it's taking load 80amps?
Hi,iam a diploma in electrical engineering.rtd from indian air force in apr 2007.prsently working in reliance next link as a network maintenance engineer since 2007,can i get a job in motherson sumi.