Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

1. Why a DC motor starter is called 3 point starter

Answer Posted / atul dattatray ahirrao

this is called as three point starter because three points L,A and F are brought out for the external connection.
Point L:it is the line terminal and should be connected to the dc supply.
point A:it is to be connected to the armature winding.
point F:it is to be connected to the feild winding.

Is This Answer Correct ?    10 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Is it possible to obtain 480v or 550v in single phase output by giving the input to 230v to a single phase torodial type transformer without using a stepup transformer?

1954


What should be the amps for a MV fuses for transformer 630kVA 20(10)/0.4 kV

1980


Is it required to lay 2 runs of GI wires along with armoured cables from one power DB Machines of higher rating?

1948


how does an encoder work???

2463


What is the effect on 3phase induction motor if current setting knob of DOL kept at minimum current?

3665


To prove the capacity of a 10MVA transforemr with 6.5% impedance by a short circuit test how much power is needed to inject an impedance voltage if we have to arrive for its rated current?

1855


what are the values of VRY,VYB,VBR,Vry,Vyb,Vbr,Vrn,Vyn,Vbn for Magenetic balance test of 100 KVA and 63 KVA Distribution transformer

2928


What happened if C.T mount at any cable or Bus bar in wrong direction . C.T going on proper work or not . C,T direction is essential thing to properly work.

1731


If i have two 3000 kW motors and the whole facility requires a 10 MVA transformer. What would be better installing two 5 MVA transformers(one for 1 motor ) or just a single 10 MVA transformer for both of them. Give reasons for your answer.

5935


Why neutral is not used in three phases dol starter

1879


along with technical test papers

1560


what is the difference betweem star connected motor & delta connected motor?

2307


Why does amplifier gain reduce?

1008


What is power distribution criteria for converting single phase unbalanced residential load to 3 phase star connected balance system. Does total KW converted to 3 Phase. Means Divided by root 3.

2263


Why different Pressure switch used in marine boiler water circulation system

1708