could i arrange a faulty and healthey battery bank togather
in parallel , if your ans is not then why?
Answer Posted / aree dewan
yes but with this connection the voltage will be constant
bur current will increase.
| Is This Answer Correct ? | 0 Yes | 2 No |
Post New Answer View All Answers
I'm generating a pulse of 3V with frequency 80Hz (12.5ms time period) and pulse duration 0.125ms and feeding it to a transformer since i want the pulse to get amplified around 60V. At the output amplification s happening but the pulse is changed to a spike, can you tell me what could be the reason? (an ordinary transformer 220V-12V stepdown transformer is reverse connected ie. now it is 12V-220V stepup and voltage amplification happens)
when the Transmission and Distribution network where is the "feeder" lines are located? and why should be used in T&D network.....
What is the difference between isolators and electrical circuit breakers? What is bus-bar?
what is the chiller and working principal
What is the formula to find out two phase active & reactive power
How do i perform grounding of star point of Genset (400V) for making connection with step up transformer of DELTA-DELTA (400V to 20KV) ? while Genset itself has its own neutral and grounding bus bar inside genset breaker box whereas we have another neutral and grounding busbar in synchronizing panel next to genset at maximum distance of 6meter, would someone pls advice if we can only perform neutral grounding in synchronizing panel or should we ground neutral on both places inside genset breaker box and synchronizing panel.
hai friends i have BSNL JTO exam on next month so if any body have model question paper or give preparation tips to my mail id kumar4486@yahoo.co.in this will helpfull for my future .plz & thank u by kumar
State nyquist stability criterion.
What is polar plot?
what is the soft starter principle? how is connection diagram? what is the procedure for checking the connection?
what are the main faults that occur in stabilizers? How they corrected and resolved ? Types of stabilizers ?
Explain the difference between verilog task and verilog function?
What descriptive information does the NEC require to be marked on all conductors?
I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?
what is the difference between oil surge relay and buchholz relay.